2000-Watt Amada Pulsar LC2415XLAII Laser Cutting System

Equipped with Fanuc C2000C Oscillator and Fanuc 16L Control

Manufactured in 1997

772-Amada-Pulsar-2415

Image 1 of 1

Request Quote

2000 Watt Amada Pulsar LC2415XLAII

The Amada Pulsar LC-2415  is a hybrid style laser cutting system with a Fanuc based control and Fanuc resonator (oscillator). Due to the unique hybrid design the Pulsar series is known for reliability and a compact footprint without sacrificing capacity.  Like all Pulsar lasers, it can reposition and the 2415 version can handle a 5′ x 12′ sheet with one auto-repositioning cycle.

Machine Specifications:

1.1 Motion Package
Travel Method: X axis for work piece movement, Y axis for cutting head movement
Control Method: X, Y & Z simultaneous 3 axis control and B axis
Drive Motors: FANUC AC Servo (X, Y, Z and B)
Maximum Sheet Size: 61″ (Y) x 198″ (X) with one repositioning cycle
Maximum Axis Travel: 61″ (Y) x 99″ (X) x 11.8″ (Z) x 0.78″ (B)
Maximum Cutting Speed: 2362 IPM
Maximum Table Speed: 3,149 IPM. Per axis (4,454″/min. 45O vector)
Maximum Speed – Z-Axis: 2362 IPM
Positioning Accuracy: 1: 0.0004″/20″
Repeatability: 0.0002″
Maximum Material Weight: 727 lbs. (5′ x 10′ x 3/8″ or 4′ x 8′ x 1/2″)
Number of Clamps: 3
Work Chute: 66″ (Y) x 21″ (X)
Assist Gas: 4 ports, part program selectable
Machine Size (WxDxH): 99″ x 225″ x 90″
Machine Weight: 13,640 lbs including laser resonator
Electrical Requirements: 208 VAC, 3 phase, 60 Hz., 10 KVA
(1) Processing accuracy will be different

1.2 CNC Controller

Model: 16LB Control (Fanuc)
Control Function: X, Y, Z, T, B & C simultaneous 3 axis Laser Power control (CW, Pulse)
Input Method: Floppy Disk, MDI, Edit, DNC
MMC Functions: Geometric Input (metric only), Maintenance
Minimum Command Unit: 0.001″ (X, Y, Z)
Minimum Travel Unit: 0.001″ (X, Y, Z)
Operating Modes: Automatic, MDI & Manual
Display Modes: Program Contents, Position Information, Program Check, Settings, Parameters, Tool Diameter Compensation, Assist Gas Status, Self Diagnostics
Interlock Displays: Water Volume, Water Temperature, Gas Pressure, Vacuum Leak, Blower  Malfunction, Shutter Power, Discharge, Assist Gas, Door Open
Electrical Requirements: 208 VAC, 3 Phase, 60 HZ, 34 KVA

Equipped With:

Chiller

Request Quote