Amada 150W QCW Fiber Laser in an AX5000 Laser Glovebox – NEVER USED!
Manufactured in 2024
Machine Number 1222
Request QuoteSpecifications QCW 150 W Laser and Optics
QCW 150 Watt rack mount fiber laser and focus head including the following:
- 150 Watt average power in pulsed or CW mode, 1.5 kW peak power, Visible guide beam, 15 J max pulse energy, Air Cooled, 100 -240 V single phase, 75 A
- One 50 um feed fiber x 10 meters long (permanently attached to laser)
- One beam coupler with 400 um process fiber x 10 meters long
- One FX100/145 focusing assembly (99-030-01), 50 mm diameter fused silica optics with 100 mm collimating and 145 mm output focal lenses
Interface with 150 W QCW Laser includes the following:
- Laser module and controller mounted in the workstation base
- Includes a resistive touchscreen HMI for laser control
- HMI will include LCD touchscreen display, key switch, ready indicator, laser alarm indicator, schedule recall, and emission indicator
Specifications Motion System
Four axis motion system; configured for your application as follows:
- 120 VAC, 50/60 Hz, 10A
- 1 in thick aluminum base plate
- Overhead gantry with welded steel supports
- Manual dual theta swivel mounting brackets – to mount focus head assembly and cameral to Z-stage
- Focus head rotation will be able to rotate between 0° (vertical down) – 90° (facing horizontal right)
- Control pendant with buttons and indicators including E-stop and motion jog buttons
- Inside ducting and nozzle for connection to fume extractor
- Electronics Control Box, mounted to back of laser glovebox
- Integration with laser
Tooling and Tooling Integration
- Specific tooling that will sit in the rotary stage
4 Axes of Programmable Motion
- 8 in X-stage
- 8 in Y-stage
- 15 in x 15 in tool plate with ¼ – 20 holes in a 2 in grid hole pattern
- 10 in Z-stage, mounted to gantry
- Direct-drive rotary stage with manual 3-jaw chuck
- Integrated 4-axis motion controller with Windows based software
- Servo drives and motors
Viewing System
PC and Software
Specifications AX5000 Atmospheric Glovebox
AX5000 four port Laser Welding Atmospheric Enclosure –featuring laser eyesafe window in compliance with CDRH Class I – 56” wide; configured as follows:
- Safety features to comply with CDRH Class I specifications
- Enclosure height modification to accommodate rotary stages
- Management Data Center; Windows operating system
- Glovebox PC with 17” LCD flat panel display, keyboard, and mouse
- 2nd Ergonomic mounting arm for PC display, keyboard and mouse
- Gas Pressure control system, GPC-110
- One End-Loading Vacuum Bakeout 200°C Oven w/ 2 heated shelves: 210-HS-2-200 (18.5″) – LEFT SIDE
- End loading Standard Vacuum Antechamber: 210-A (18.5″) – RIGHT SIDE
- One Model 15i Dry Vacuum Pump Assemblies – 15.1 m3/hr
- Two Coolmate 3 water re-circulator; for cooling oven door flanges, GP-500 gas dryer, and fume removal system
- Moisture Monitor – integrated
- Oxygen Analyzer (PPM) – Integrated
- Two Gas Mixing System (Electronic Helium Dosing, Self-Circulating)
- Helium Monitor (w/ Nitrogen) – HE-20-N – integrated
- Glovebox interior power strip – 220VAC; IEC 60320 Plug Type
- Loss of Pressure Safety Value Shutoff
- GP-500-PLUS 2-Column Auto Regeneration Gas Purification System – P/N: GP-500A-P-DUAL + glovebox integration
- 30 CFM Fume removal system
- Bulkhead interface plate with all required hermetic connectors for integration with motion system and fiber laser welder
- Heavy duty welded Steel Frame machine base with leveling feet