Mitsubishi NX Series Laser

The Mitsubishi NX series was the top of the line high-speed CO2 laser system equipped with a high speed precision rack and pinion drive with linear Z-axis. This machine is the ML-3015 model equipped with 5′ x 10′  shuttle tables and 6000-watt resonator.  The extra power will help cut  heavier materials and improve speeds and cut  quality with nitrogen.

Machine  Specifications

Machine structure: Precision rack and pinion with linear Z-axis
Travel drive method: X,Y,Z simultaneous 3 axes
Control method: X,Y, and Z simultaneous 3 axis control
X-Axis stroke: 125.98”
Y-Axis stroke: 62.99”
Z-Axis stroke: 4.7”
Maximum work piece size: 120.08” x 60.04”
Maximum processing feed rate: 2360 inches per minute
Maximum work piece weight: 2050 lbs.
Table pass height: 33.5”
Rapid travel speed
Single axis; 4724 inches per minute
Simultaneous: 6680 inches per minute
Minimum command input: .001 mm/.0001”
Drive motor type: Intelligent AC servo
Machine unit dimensions: 444.1”L x 94.5” H x 193.8” D
Total system weight: 34,836 lbs.
Pallet change time: approximately 35 seconds
Pallet change weight: 6175 lbs.
Pallet changer drive mechanism: chain
Installation dimensions: 489.6” x 346.8”
Floor space requirement: 1179 sq. ft.
Electrical requirements: 208 VAC +/- 5%, 3 phase, 60 Hz
Motion system, CNC controller: 98 KVA (Total Machine Usage)
Laser resonator: 280 (full load AMPs)

CNC  Control  Specifications

Model: Mitsubishi LC20BP2
Type: self contained-simple dust proof design
CPU: 64 Bit
Display unit: 15.0” TFT color LCD touch screen
Hard disc drive capacity: 10.0 GB
Program memory capacity: Standard 5000m/Approximately 2 MB, number of register able programs 400
CO2 Laser control
Power control: output power, frequency, duty
Operation control: shutter open/close, beam on/off, laser gas change, etc…
Processing machine control
Drive method: X, Y, Z (simultaneous control)
Position detection method: encoder
Minimum command unit: .001mm/.0001”
Program input method: USB, computer link, Ethernet LAN
Operation Method: memory operation/HD direct operation